MiniMed Champion
MiniMed™ 780G insulin pump system
Life with type 2 diabetes just got easier
for people who use insulin. Now cleared with the Instinct sensor, made by Abbott.
Spend less time and effort managing diabetes
Check out these benefits of automated insulin delivery with the MiniMed 780G system:

Meal Detection™ technology‡ automatically adjusts insulin when you undercount carbs or forget to dose — these automatic adjustments help prevent post-meal highs.

Skip daily injections with a pump featuring a 300 mL reservoir, for higher insulin needs, and a 7-day infusion set for fewer changes. Compatible with the 15-day-wear Instinct sensor.

Sleep better with a system that anticipates, adjusts, and corrects all day and night.†
Understanding how insulin pumps work
Explore how insulin pump therapy simplifies diabetes management by delivering precise, automated insulin adjustments to the body through a thin, flexible tube called an infusion set.
Benefit from 24/7 glucose control with insulin pump therapy
Stress less about perfect carb counts with the system that automatically gives you extra insulin if you need it.§
Leave behind the hassle of multiple daily injections with our automated insulin pump that works in the background, reducing the mental load of diabetes care and helping you spend more Time in Range.
Get started
MiniMed Champion
The MiniMed™ 780G system components
Life with insulin-dependent type 2 diabetes, and stories that inspire.
Our technology empowers your journey, turning old routines into new freedom by simplifying diabetes management.
“The MiniMed™ 780G system has simplified the management of my diabetes. It all but eliminated the need for finger sticks in SmartGuard™ technology,¶ and it manages my insulin delivery every five minutes around the clock with auto corrections."
Larry, MiniMed Champion and T2DGet notified of highs and lows
Our mobile apps seamlessly connect the insulin pump system together with your smartphone and Apple® Watch to keep you in the know!
You will be able to display key insulin pump data right on your compatible smart device! Discover a new way to interact with your MiniMed™ insulin pump and continuous glucose monitoring (CGM) data.
Designed for care partners, this provides an easy way to remotely view the glucose levels and insulin pump information of a person with diabetes.
| Water resistance | At the time of manufacture and when the reservoir and tubing are properly inserted, your pump is waterproof. It is protected against the effects of being underwater to a depth of up to 8 feet (2.4 meters) for up to 30 minutes. This is classified as IPX8 rating. See user guide for more details. The sensor and transmitter are water-resistant at 8 feet (2.4 meters) for up to 30 minutes. CGM readings may not be transmitted from the CGM to the pump while in water. Note: Do NOT take your Sensor deeper than 3 feet (1 meter) or immerse it longer than 30 minutes in water. Bluetooth performance may be impacted if using the system while underwater. The pump is not intended for submersion in water and is expected to be removed prior to swimming or bathing. |
|---|---|
| Environmental conditions | The MiniMed™ 780G insulin pump system is designed to withstand most conditions encountered in your daily life. Pump operating temperature range is from 41 °F (5 °C) to 98.6 °F (37 °C). Pump storage temperature range is from -4° F (-20° C) to 122° F (50° C). Air pressure range is from 700 hPa to 1060 hPa (10.2 psi to 15.4 psi). |
| Altitude range |
|
| Insulin type | Rapid-acting U100 insulin (Humalog® and NovoLog®) that has been prescribed by a healthcare professional. |
| Bolus delivery | Bolus Speeds
|
| Programming increments |
|
| Basal rate delivery | 0 to 35 units per hour or the Max Basal Rate amount, whichever is lower. |
| Screen |
|
| Battery & power | The pump requires one new AA (1.5 V) battery. For best results, use a new AA lithium (FR6) battery. The pump also accepts an AA alkaline (LR6) or a fully charged AA NiMH (HR6) nickel-metal hydride rechargeable battery. |
| Pump memory | At any time, you can review 30 days of pump history. |
| Size | The pump dimensions in inches are approximately 2.1 width x 3.78 length x 0.96 depth. The weight of the pump is approximately 3 ounces. |
| Warranty |
|
Compatible products |
|
| Reservoir | Medtronic reservoir MMT-332A, 3.0 ml (300-units), Medtronic reservoir MMT0326A, 1.8 ml (180-units). |
| Infusion sets | Medtronic Diabetes offers a wide range of infusion sets so that you can choose the right one for your comfort and safety. |
MiniMed insulin pumps are covered by most insurance plans. Your out-of-pocket cost varies depending on your insurance. We also offer financial assistance and monthly payment programs. If you would like to check your insurance coverage, call us at 1-888-350-5440 (M-F, 9 a.m. to 6 p.m.).
For customers currently on a MiniMed insulin pump, sign in to Diabetes.shop to see your options.
If you currently use an in-warranty insulin pump from another manufacturer, you may be eligible for our Switch2System program when you trade in your current device.
Simply trade in your existing pump and pay an upgrade fee of just $499 to switch to the MiniMed™ 780G system. If it doesn’t work out, no problem! You have 90 days to see if the system is right for you or you can return it. Learn more about our Switch2System program.
Yes, the MiniMed™ 780G system is covered by Medicare and Medicare Advantage.
For new customers looking to order the MiniMed™ 780G system, fill out our form.
For customers currently on a MiniMed insulin pump, sign in to Diabetes.shop to see your options.
MiniMed™ 780G system is for type 1 ages 7 and over and type 2 ages 18 and over.
Following your diabetes treatment plan and monitoring your glucose are important daily steps to take to prevent hyperglycemia concerns. However, the MiniMed™ 780G system features Meal Detection™ technology‡ that can detect if you’ve missed a meal dose and give you more insulin when you need it to help reduce post-meal hyperglycemia.† Always consult your healthcare team to find out what treatment is right for you.
To check if your smartphone or your Apple® Watch models are compatible, please visit our compatibility tool.
MiniMed™ Mobile app for people living with diabetes:
View your diabetes data on your smartphone or Apple® Watch, so you can easily track your glucose levels and get notified if you’re trending high or low. The app also enables automatic uploads of pump and CGM data to CareLink™ software so you can view trends and access reports about your system.
If you are a healthcare professional, we encourage you to visit our Diabetes professional website.
Footnotes
† Refers to auto correct, which provides bolus assistance. Can deliver all correction doses automatically without user interaction, feature can be turned on and off.
‡ Taking a bolus 15 – 20 minutes before a meal helps to keep blood sugar levels under control after eating.
§ Refers to SmartGuard™ feature. Individual results may vary.
◊ Assumes 4 injections per day for 30 days and one infusion set change every two to three days.
¶ Fingersticks required in manual mode & to enter smartguard. If symptoms don’t match alerts & readings, use a fingerstick. Refer to user guide. Pivotal trial participants spend avg of > 93% in SmartGuard.
References
- Thijs I, et al. JDST. 2025. https://doi.org/10.1177/193229682513183
Important Safety Information: MiniMed™ 780G system with SmartGuard™ technology with Instinct sensor, Simplera Sync™ sensor, and Guardian™ 4 sensor
The MiniMed™ 780G system is intended for the continuous delivery of basal insulin at selectable rates and the administration of insulin boluses at selectable rates for the management of type 1 diabetes mellitus in persons 7 years of age and older, and of type 2 diabetes mellitus in persons 18 years of age and older requiring insulin. The system is also intended to continuously monitor glucose vales in the fluid under the skin.
The MiniMed™ 780G System includes SmartGuard™ technology, which can be programmed to automatically adjust insulin delivery based on the continuous glucose monitoring (CGM) sensor glucose values and can suspend delivery of insulin when the sensor glucose (SG) value falls below or is predicted to fall below predefined threshold values. The system is intended for use with connected sensors, including the Simplera Sync™ and Guardian™ 4 sensors and integrated continuous glucose monitors, including the Instinct sensor, each of which has different wear-time, form factor, insertion site, and other distinguishing characteristics that relate to sensor performance. Consult the appropriate sensor user guide when using the system. Discuss treatment decisions with your HCP.
WARNING: Do not use the SmartGuard™ feature for people who require less than 8 units or more than 250 units of total daily insulin per day. A total daily dose of at least 8 units, but no more than 250 units, is required to operate in the SmartGuard™ feature.
WARNING: Do not use the MiniMed™ 780G system until appropriate training has been received from a healthcare professional. Training is essential to ensure the safe use of the MiniMed™ 780G system.
WARNING: Do not use SG values to make treatment decisions, including delivering a bolus, while the pump is in Manual Mode. When the SmartGuard™ feature is active and you are no longer in Manual Mode, the pump uses an SG value, when available, to calculate a bolus amount. However, if your symptoms do not match the SG value, use a blood glucose (BG) meter to confirm the SG value. Failure to confirm glucose levels when your symptoms do not match the SG value can result in the infusion of too much or too little insulin, which may cause hypoglycemia or hyperglycemia.
Pump therapy is not recommended for people whose vision or hearing does not allow for the recognition of pump signals, alerts, or alarms. The safety of the MiniMed™ 780G system has not been studied in pregnant women or in persons using other anti-hyperglycemic therapies that do not include insulin. For complete details of the system, including accessories and additional important safety information concerning indications, contraindications, warnings and precautions associated with the system and its components, please consult https://www.medtronicdiabetes.com/important-safety-information and the appropriate user guides at https://www.medtronicdiabetes.com/download-library.
© Medtronic. MiniMed and MiniMed logo are trademarks of Medtronic MiniMed, Inc. The sensor shape and appearance, Abbott, and “a” logo are marks and/or designs of the Abbott group of companies in various territories and used under license. Sensor image © Abbott. ™*Third–party brands are trademarks of their respective owners.


